Periodic inspection of fire extinguishers

BGCPSE23SIS
€20,00
10% extra discount on the total in the cart for customers in the "Maintenance - Wholesalers - Resellers" group
In stock
1
Product Details
Type: Fire protection services
The efficiency of the fire extinguisher must be checked every six months through specific technical checks. This phase of maintenance is called periodic inspection. This is why a professional maintenance technician is needed for these activities.
The physical condition of the fire extinguisher and its components must also be checked. For example, in the control phase the internal pressurization conditions are ascertained.
This phase is regulated by law, both for the project that must be carried out and for the periodicity. It must be performed by a competent person, with a maximum frequency of six months. By the end of the sixth month, it is necessary to check the efficiency of all types of portable or wheeled fire extinguishers, without carrying out function tests.
It consists of an activity aimed at verifying, with a maximum periodicity of 6 months (by the end of the month in question) the efficiency of portable and wheeled fire extinguishers by means of:

a) Verifications referred to in the surveillance phase
b) For pressurized fire extinguishers with permanent pressure, internal pressure control with an independent pressure gauge
c) For carbon dioxide extinguishers, checking the state of charge by weighing
d) For extinguishers with auxiliary gas (internal and/or external cylinder) cylinder charge control by weighing.
e) The extinguisher does not show anomalies such as clogged nozzles, pressure losses, traces of corrosion, disconnection or cracks in the flexible hoses.
f) The support is free from damage and the transport handle in particular, if on wheels, has working wheels
g) Is free from damage and dents to the tank.
h) The instruments used for the checks (manometers and scales) must be calibrated and/or verified, at specified intervals, or before their use, against standard measuring instruments.

Records of calibration and verification results must be maintained.

Any anomalies found must be eliminated immediately, otherwise, the fire extinguisher must be declared unsuitable by placing a "EXTINGUISHER OUT OF SERVICE" label on the appliance, also informing the responsible person and reporting "OUT OF SERVICE" on the maintenance tag.

At the end of the work, the technician will sign and date the tag, in parallel with the annotation in the Maintenance Register of all the activities carried out.

Save this product for later

Fields of application

Biogenesis is a company specialized in fire prevention and protection: it provides 360° services, products and solutions in the field of safety and fire prevention. Discover the solutions that best suit your needs, a wide range of products is available to satisfy every type of application.

Residential buildings

Inside a home, the risk of a fire spreading is always lurking. Faulty electrical systems, low quality appliances, stove fires etc. We offer a wide range of fire protection products and solutions to suit your needs.

Hotels and Restaurants

In these environments it is essential that fire protection is carried out not only with prevention rules, but also with the correct supply of equipment and devices capable of promptly extinguishing the flames that can flare up at any time.

Hospitals

A hospital, at any moment, is full of people, patients and medical staff. In a fire situation, oxygen tanks, gas, bandages, linens and medicines on the hospital premises feed the fire, pushing it out of control.

Server rooms

With so many computer systems and associated components, such as telecommunications and storage systems, in one location, the possibilities of fire are very real. And the slightest problem could lead to the loss of large amounts of data and operational disruption.

Offshore platforms

Fire poses a significant risk aboard offshore drilling platforms and platform support vessels. The nature of the equipment and its thermal characteristics can easily transform malfunctions into fires which can be life threatening.

Naval and military industry

Imagine a fire developing on a ship in the middle of the ocean: the impact would be potentially catastrophic. For military vehicles, uncontrolled fire is one of the greatest threats to life and property. In this context it is necessary to have safe and reliable fire fighting equipment.

Do you need support?

Contact us now! Our experts are at your complete disposal to guide you in choosing the most suitable product for your fire-fighting needs.
Contact us now

Biogenesis Srl

Biogenesis is a company specialized in fire prevention and protection: it provides 360° services, products and solutions in the field of safety and fire prevention. A unique reality for products, solutions and services in the field of safety and fire prevention.

Fire suppression system

We offer turnkey solutions for fire protection, designed supplied and installed complete and immediately operational.

Fire maintenance

Biogenesis guarantees a global assistance service that aims to respond to all customer needs.

Door Fan Test

Biogenesis performs the door fan test in compliance with all current regulations.

Certified quality

All of our products comply with the highest quality standards.

Fire extinguishers

Biogenesis offers a complete range of approved portable and wheeled fire extinguishers for any type of application.

Halon and F-GAS bank

Biogenesis, world leader in the fire-fighting sector, is also an “authorised halon and FGAS collection centre”.

Specialised personnel

Biogenesis personnel is highly qualified for any type of firefighting intervention.

24/7 support

Our technicians are always ready to face any fire-fighting requirement.